0

EITA&PAUL

INNOVATION

MTZ208H16X3PMD
Back
MTZ208H16X3PMD  Circuit breaker, MasterPact MTZ2 08H1 (66kA/415VAC), 3P, 800A, drawout, manually operated, MicroLogic 6.0X control unit
SKU
รหัสสินค้า
MTZ208H16X3PMD
Stock
จำนวนสินค้า
SOLD
Shipping
ค่าจัดส่ง
FREE
฿208,000.00 (Discount 50%)
Price ฿104,000.00
รายละเอียดสินค้า
Main
Range MasterPact
Product name MasterPact MTZ2
Device short name MTZ2 08 H1
Product or component type Circuit breaker
Device application Distribution
Poles description 3P
Protected poles description 3D
[In] rated current 800 A at 50 °C
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation Yes conforming to EN/IEC 60947-2
utilisation category Category B
[Icu] rated ultimate short-circuit breaking capacity 66 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA Icu at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA Icu at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level H1 66 kA 415 V AC
Trip unit name MicroLogic 6.0 X
Trip unit technology Electronic
Trip unit protection functions LSIG
control type Manually operated
ON/OFF push-button
Mounting mode Drawout
Complementary
[Ui] rated insulation voltage 1000 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage 12 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity 66 kA at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Icw] rated short-time withstand current 66 kA 0.5 s conforming to EN/IEC 60947-2
66 kA 1 s conforming to EN/IEC 60947-2
36 kA 3 s conforming to EN/IEC 60947-2
[Icm] rated short-circuit making capacity 145 kA (Icm) at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
145 kA (Icm) at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
145 kA (Icm) at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2
145 kA (Icm) at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Maximum breaking time 25 ms
maximum closing response time 70 ms
Mechanical durability 25000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-2
Electrical durability 10000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
10000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Power dissipation per pole 100 W
mounting support Base plate
Rails
Upside connection Rear
Vertical
downside connection Rear
Vertical
Connection pitch 115 mm
Protection type Overload protection (long time) conforming to ANSI 49
Instantaneous short-circuit protection conforming to ANSI 50
Short time short-circuit protection conforming to ANSI 51
Earth fault conforming to ANSI 51N
Trip unit rating 800 A at 50 °C
[Ir] long-time protection pick-up adjustment range 0.4...1 x In adjustable in step of 1 A
Long-time protection delay adjustment type tr Adjustable in step of 0.5 s
[tr] long-time protection delay adjustment range 12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.34…16.6 s at 7.2 x Ir
Thermal memory Yes
[Isd] Short-time protection pick-up adjustment range 1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI
Short-time protection delay adjustment type tsd Adjustable
[tsd] Short-time protection delay adjustment range 0.1…0.4 s I²t=on
0…0.4 s I²t=off
[Ii] instantaneous protection pick-up adjustment range 2...15 x In adjustable in step of 0.5 x In with embedded HMI
Ii enable on/off
[li mode] instantaneous delay adjustment range 20...50 ms in standard
[Ig] ground-fault protection pick-up adjustment range With In > 400 A 0.2...1 x In adjustable in step of 0.1 x In
with In <= 400 A 0.3...1 x In adjustable in step of 0.1 x In
Ig enable on/off
Ground-fault time delay adjustment type Adjustable
[tg] ground-fault protection time delay adjustment range 0.1…0.4 s I²t=on
0…0.4 s I²t=off
earth-leakage protection Without
Zone selective interlocking ZSI With
Network and machine diagnosis type System (HMI) health state overview: circuit breaker health state standard)
Contacts state: circuit breaker health state standard)
MicroLogic service life: circuit breaker health state standard)
Tripping cause indication: circuit breaker tripping cause standard)
Identification card: diagnostic data standard)
Configured alarms synthesis: diagnostic data standard)
Monitored function: diagnostic data standard)
Operation: diagnostic data standard)
MicroLogic test: test standard)
Protection test: test standard)
Selectivity test: test standard)
Trip context information: crisis management standard)
Operation: advanced diagnostic standard)
Breaker service life: circuit breaker health state standard)
Type of measurement Power meter
Energy management Measurement ,active, reactive and apparent energy (standard)
Measurement ,electrical network (standard)
Measurement ,energy (standard)
Metering type Current I1, I2, I3, In, Ig: maximum standard)
Average voltage Vavg standard)
Active power P, P1, P2, P3 standard)
Reactive power Q, Q1, Q2, Q3 standard)
Apparent power S, S1, S2, S3 standard)
Power factor standard)
Frequency standard)
Total current harmonic distortion THD (I): inst, avg, avg min, avg max fundamental voltage standard)
Total current harmonic distortion THD (I): inst, avg, avg min, avg max RMS voltage standard)
Voltage V21, V32, V13, V1, V2, V3: instantaneous standard)
Voltage V21, V32, V13, V1, V2, V3: minimum standard)
Voltage V21, V32, V13, V1, V2, V3: maximum standard)
Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max fundamental voltage standard)
Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max RMS voltage standard)
Demand current I1, I2, I3, In, Iavg standard)
Demand power P, Q, S standard)
Measurement voltage 145.6…828 V AC 50/60 Hz per phase
Frequency measurement range 45…250 Hz
Measurement accuracy Power factor: +/- 1 %
Active energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh
Reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh
Apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh
Unbalance current: +/- 0.5 %
Frequency: +/- 0.005 Hz
Voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V
Voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V
Apparent power S, S1, S2, S3, Sdemand: +/- 1 %
Active power P, P1, P2, P3, Pdemand: +/- 1 %
Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %
Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A
Accuracy class Class 5: total current harmonic distortion THD (I)
Class 0.5: unbalance voltage
Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h)
Class 2: total voltage harmonic distortion THD (V)
Display type LCD display - 128 x 96 pixels
Local signalling 3 LEDs (red) for trip causes
1 LED (red/orange) for overload
1 LED (green) for ready to operate
1 LED (red/orange) for service
Communication port protocol Bluetooth 4.0 LE peer to peer 30 kbit/s conforming to IEEE 802.15.1
NFC peer to peer 28800 bauds conforming to ISO 15963
USB peer to peer 115 kbauds
data recording Min/max of instantaneous values
Alarm logs
Maintenance logs
Event logs
Time stamping
Data logs
Commissioning interface EcoStruxure Power Commission
end user smartphone application EcoStruxure Power Device
Locking options description Padlock in OFF position
Keylock in OFF position
Provision for padlocking 3 padlocks
Width (W) 422 mm
Height (H) 352 mm
Depth (D) 300 mm
Net weight 90 kg
Environment
standards EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 61010-1
product certifications IECEE CB Scheme
Pollution degree 3 conforming to EN/IEC 60947-1
Overvoltage category IV conforming to EN/IEC 61010-1
IP degree of protection IP30 conforming to EN/IEC 60529
IK degree of protection IK07 conforming to EN/IEC 62262
Environmental characteristic Wet location not approved for use conforming to EN/IEC 61010-1
Electromagnetic compatibility Electrostatic discharge immunity test conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5
Conducted RF disturbances A conforming to EN/IEC 61000-4-6
Conducted and radiated emissions conforming to CISPR 22
Measurement category Category IV conforming to IEC 61010-2-30
Ambient air temperature for operation -25…70 °C (operating)
-35 °C (for start-up of product)
Ambient air temperature for storage -40…85 °C
Relative humidity 0…95 % conforming to IEC 60068-2-30
Operating altitude <= 2000 m without derating
<= 3000 m 99 % of In
<= 4000 m 96 % of In
<= 5000 m 94 % of In
Packing Units
Unit Type of Package 1 PCE
Number of Units in Package 1 1
Package 1 Height 70 cm
Package 1 Width 60 cm
Package 1 Length 80 cm
Package 1 Weight 90 kg


เลขที่ 219 ห้องเลขที่10 ถนนเทิดไทย  แขวงบางยี่เรือ เขตคลองสาน ประเทศไทย 10600
บริษัท เอตะ แอนด์ พอล อินโนเวชั่น จำกัด