MTZ220H16X3PMF
Back
MTZ220H16X3PMF
Main
Range
MasterPact
Product name
MasterPact MTZ2
Device short name
MTZ2 20 H1
Product or component type
Circuit breaker
Device application
Distribution
Poles description
3P
Protected poles description
3D
[In] rated current
2000 A at 50 °C
[Ue] rated operational voltage
690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Suitability for isolation
Yes conforming to EN/IEC 60947-2
utilisation category
Category B
[Icu] rated ultimate short-circuit breaking capacity
66 kA Icu at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA Icu at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA Icu at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Performance level
H1 66 kA 415 V AC
Trip unit name
MicroLogic 6.0 X
Trip unit technology
Electronic
Trip unit protection functions
LSIG
control type
Manually operated
ON/OFF push-button
Mounting mode
Drawout
Complementary
[Ui] rated insulation voltage
1000 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Uimp] rated impulse withstand voltage
12 kV conforming to EN/IEC 60947-2
[Ics] rated service short-circuit breaking capacity
66 kA at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2
66 kA at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Icw] rated short-time withstand current
66 kA 0.5 s conforming to EN/IEC 60947-2
66 kA 1 s conforming to EN/IEC 60947-2
36 kA 3 s conforming to EN/IEC 60947-2
[Icm] rated short-circuit making capacity
145 kA (Icm) at 220/415 V AC 50/60 Hz conforming to EN/IEC 60947-2
145 kA (Icm) at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
145 kA (Icm) at 500/525 V AC 50/60 Hz conforming to EN/IEC 60947-2
145 kA (Icm) at 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Maximum breaking time
25 ms
maximum closing response time
70 ms
Mechanical durability
20000 cycles with periodic preventive maintenance conforming to EN/IEC 60947-2
Electrical durability
8000 cycles 440 V AC 50/60 Hz conforming to EN/IEC 60947-2
6000 cycles 690 V AC 50/60 Hz conforming to EN/IEC 60947-2
Power dissipation per pole
470 W
mounting support
Base plate
Rails
Upside connection
Rear
Vertical
downside connection
Rear
Vertical
Connection pitch
115 mm
Protection type
Overload protection (long time) conforming to ANSI 49
Instantaneous short-circuit protection conforming to ANSI 50
Short time short-circuit protection conforming to ANSI 51
Earth fault conforming to ANSI 51N
Trip unit rating
2000 A at 50 °C
[Ir] long-time protection pick-up adjustment range
0.4...1 x In adjustable in step of 1 A
Long-time protection delay adjustment type tr
Adjustable in step of 0.5 s
[tr] long-time protection delay adjustment range
12.5…600 s at 1.5 x Ir
0.5…24 s at 6 x Ir
0.34…16.6 s at 7.2 x Ir
Thermal memory
Yes
[Isd] Short-time protection pick-up adjustment range
1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI
Short-time protection delay adjustment type tsd
Adjustable
[tsd] Short-time protection delay adjustment range
0.1…0.4 s I²t=on
0…0.4 s I²t=off
[Ii] instantaneous protection pick-up adjustment range
2...15 x In adjustable in step of 0.5 x In with embedded HMI
Ii enable on/off
[li mode] instantaneous delay adjustment range
20...50 ms in standard
[Ig] ground-fault protection pick-up adjustment range
With In > 400 A 0.2...1 x In adjustable in step of 0.1 x In
with In <= 400 A 0.3...1 x In adjustable in step of 0.1 x In
Ig enable on/off
Ground-fault time delay adjustment type
Adjustable
[tg] ground-fault protection time delay adjustment range
0.1…0.4 s I²t=on
0…0.4 s I²t=off
earth-leakage protection
Without
Zone selective interlocking ZSI
With
Network and machine diagnosis type
System (HMI) health state overview: circuit breaker health state standard)
Contacts state: circuit breaker health state standard)
MicroLogic service life: circuit breaker health state standard)
Tripping cause indication: circuit breaker tripping cause standard)
Identification card: diagnostic data standard)
Configured alarms synthesis: diagnostic data standard)
Monitored function: diagnostic data standard)
Operation: diagnostic data standard)
MicroLogic test: test standard)
Protection test: test standard)
Selectivity test: test standard)
Trip context information: crisis management standard)
Operation: advanced diagnostic standard)
Breaker service life: circuit breaker health state standard)
Type of measurement
Power meter
Energy management
Measurement ,active, reactive and apparent energy (standard)
Measurement ,electrical network (standard)
Measurement ,energy (standard)
Metering type
Current I1, I2, I3, In, Ig: maximum standard)
Average voltage Vavg standard)
Active power P, P1, P2, P3 standard)
Reactive power Q, Q1, Q2, Q3 standard)
Apparent power S, S1, S2, S3 standard)
Power factor standard)
Frequency standard)
Total current harmonic distortion THD (I): inst, avg, avg min, avg max fundamental voltage standard)
Total current harmonic distortion THD (I): inst, avg, avg min, avg max RMS voltage standard)
Voltage V21, V32, V13, V1, V2, V3: instantaneous standard)
Voltage V21, V32, V13, V1, V2, V3: minimum standard)
Voltage V21, V32, V13, V1, V2, V3: maximum standard)
Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max fundamental voltage standard)
Total voltage harmonic distortion THD (V): inst, avg, avg min, avg max RMS voltage standard)
Demand current I1, I2, I3, In, Iavg standard)
Demand power P, Q, S standard)
Measurement voltage
145.6…828 V AC 50/60 Hz per phase
Frequency measurement range
45…250 Hz
Measurement accuracy
Power factor: +/- 1 %
Active energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh
Reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh
Apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh
Unbalance current: +/- 0.5 %
Frequency: +/- 0.005 Hz
Voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V
Voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V
Apparent power S, S1, S2, S3, Sdemand: +/- 1 %
Active power P, P1, P2, P3, Pdemand: +/- 1 %
Reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 %
Current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A
Current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A
Accuracy class
Class 5: total current harmonic distortion THD (I)
Class 0.5: unbalance voltage
Class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h)
Class 2: total voltage harmonic distortion THD (V)
Display type
LCD display - 128 x 96 pixels
Local signalling
3 LEDs (red) for trip causes
1 LED (red/orange) for overload
1 LED (green) for ready to operate
1 LED (red/orange) for service
Communication port protocol
Bluetooth 4.0 LE peer to peer 30 kbit/s conforming to IEEE 802.15.1
NFC peer to peer 28800 bauds conforming to ISO 15963
USB peer to peer 115 kbauds
data recording
Min/max of instantaneous values
Alarm logs
Maintenance logs
Event logs
Time stamping
Data logs
Commissioning interface
EcoStruxure Power Commission
end user smartphone application
EcoStruxure Power Device
Locking options description
Padlock in OFF position
Keylock in OFF position
Provision for padlocking
3 padlocks
Width (W)
422 mm
Height (H)
352 mm
Depth (D)
300 mm
Net weight
90 kg
Environment
standards
EN/IEC 60947-1
EN/IEC 60947-2
EN/IEC 61010-1
product certifications
IECEE CB Scheme
Pollution degree
3 conforming to EN/IEC 60947-1
Overvoltage category
IV conforming to EN/IEC 61010-1
IP degree of protection
IP30 conforming to EN/IEC 60529
IK degree of protection
IK07 conforming to EN/IEC 62262
Environmental characteristic
Wet location not approved for use conforming to EN/IEC 61010-1
Electromagnetic compatibility
Electrostatic discharge immunity test conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields conforming to EN/IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test conforming to EN/IEC 61000-4-5
Conducted RF disturbances A conforming to EN/IEC 61000-4-6
Conducted and radiated emissions conforming to CISPR 22
Measurement category
Category IV conforming to IEC 61010-2-30
Ambient air temperature for operation
-25…70 °C (operating)
-35 °C (for start-up of product)
Ambient air temperature for storage
-40…85 °C
Relative humidity
0…95 % conforming to IEC 60068-2-30
Operating altitude
<= 2000 m without derating
<= 3000 m 99 % of In
<= 4000 m 96 % of In
<= 5000 m 94 % of In
Packing Units
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
70 cm
Package 1 Width
60 cm
Package 1 Length
80 cm
Package 1 Weight
90 kg
SKU
รหัสสินค้า
MTZ220H16X3PMF
Stock
จำนวนสินค้า
SOLD
Shipping
ค่าจัดส่ง
FREE
฿223,760.00 (Discount 50%)
Price ฿111,880.00